The Economics of Centralized Automatic Fetal Monitoring

Kazuo Maeda

Published Date: 2016-08-10
DOI10.21767/2471-9927.100011
Kazuo Maeda*

Department of Obstetrcs and Gynecology (Emeritus), Tottori University Medcal School, Yonago, Japan

*Corresponding Author:
Kazuo Maeda
Department of Obstetrcs and Gynecology (Emeritus)
Tottori University Medcal School, Yonago, Japan
Tel: 81 857-31-5007
E-mail: maedak@mocha.ocn.ne.jp

Received Date: June 27, 2016; Accepted Date: August 3, 2016; Published Date: August 10, 2016

Citation: Maeda K. The Economics of Centralized Automatic Fetal Monitoring. J Health Med Econ. 2016, 2:11

Copyright: © 2016 Kazuo Maeda, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Visit for more related articles at Journal of Health & Medical Economics

Abstract

Aims: Economical conditions were compared between individual human fetal monitoring and computerized montoring of intrapartum fetus.

Methods: Economical conditions were compared in personal monitoring with obstetrical staffs and the central computerized simultaneous monitoring in multiple births.

Results: Clinical results were the decrease of perinatal mortality and the zero case of cerebral palsy in the present update computer system comparing previous computer system.. Economical expense calculation showed 4292 USD lower expense in the computerized monitoring than the visual CTG watching monitoring.

Keywords

Fetus; FHR; Central computer, Automatic analysis; Rapid and direct reporting; Outcome; Improvement; Economics

Introduction

Although human observation, analysis and diagnosis of continuously recorded fetal heart rate was common fetal monitoring, which resulted the reduction of perinatal mortality, neonatal asphyxia, and even reduced cerebral palsy [1,2], continuous intrapartum fetal monitoring of cardiotocobram (CTG) of obstetrician or obstetric staff was time-consuming, troublesome and endless work in obstetrics. Therefore, various computerized automatic fetal monitorings were reported starting from the author around in 1975 using a minicomputer. The author and co-authors developed automatic program to calculate FHR score [3], to analyze further objective artificial neural network [4], analyzing frequency spectrum to diagnose pathologic sinusoidal FHR [5] and to predict the loss of FHR variability [6], and they were accumulated in an centralized automatic computer system with 100 channel time sharing to analyze multiple fetuses in pregnancy and labor with doctor-direct reporting system, which was actually tested in a hospital resulting reduction of perinatal mortality and zero case of cerebral pasy, which was better than previous computer system [7], while the system was rather expensive than CTG watching system therefore, the author tried to compare the expenses of traditional fetal monitoring to the update computerized monitoring in this article.

Methods

Traditional fetal monitoring was the monitoring of individual birth recording personal CTG, of which record is continuously watched by trained staffs in obstetrics, detecting pathologic FHR signs to report the attendant physician. There was a simple computer system, of which model name was MT140, attached to single CTG monitor, only calculate the FHR score of single subject, composed of micro-computer, without alarming function, designed by Maeda and provided by TOITU (Tokyo) in late 1970s.

A typical automatic FHR monitorig computer system is as follpws Each FHR and contraction data are transferred from the woman in pregnancy or labor to the central computer by LAN or telemetry, where the data are received by 100 channel time sharing system, and analysed in each channel, in which FHR details are detected, FHR score is calculated, that is abnormal if it is 15 or more and the result is confirmed by the more objective neural network analysis system. Pathologic sinusoidal heart rate and decreased variability are diagnosed by frequency spectrum analysis of FHR baseline, common FHR patterns are diagnosed by an FHR analyzing computer, where pathologic results are detected to alarm attendant doctor calling registered address directly and rapidly. The physician indicates necessary treatments promptly by the alarming report of computer [7].

Results

Simultaneous multiple births were automatically diagnosed using TOITU’s software (TOITU, Tokyo), where perinatal mortality decreased significantly than previous computer system, and cerebral palsy was zero in the new system of rapid and direct reporting computer [7].

Economics

The expenses paid for the machines and nurses of individual monitoring and above listed automatic monitoring system are compared in the monitoring of 20 simultaneous births, which will be 7,000 births in a year. It looks like to pay more to the computer in the first year (Table 1), however, the expense is 4292 USD less in the computer than individual monitoring with human power (Table 2).

Table 1: Expenses paid for 7,000 birth (daily 20 births) in the computer system and individual human fetal monitoring.

Centralized Computer system Individual monitoring
The first year
Central computer system
20000 USD
Patient set 100000 USD
Copy paper = 4 USD
Central nurse x1 = 120 USD
( 20 fetal monitors have been set)
Employ 20 Nurses: 24000 USD
Recorder paper x 20=40 USD
Record filing room 4700 USD
Total 120124 USD Total 28740 USD

Table 2: Expenses in 5 years after introduction of computer system.

Centralized Computer system Individual monitoring
Further 4 years
Copy paper 4 USD
Central nurse 120 USD x4
= 480 USD
Employ 20 nurses for 4 years:
24000x 4 = 96000 USD
Recorder paper 40 x4 = 160USD
Total in 5 years
120608 USD 124900 USD

Therefore, computerized monitoring will be recommendable, because computerized monitoring has various advantages, because computer does not sleep nor tired, the results are objective and detailed.

References

open access journals, open access scientific research publisher, open access publisher
Select your language of interest to view the total content in your interested language

Viewing options

Flyer image

Share This Article

paper.io

agar io

wowcappadocia.com
cappadocia-hotels.com
caruscappadocia.com
brothersballoon.com
balloon-rides.net

wormax io